EUCHNER Transponder-coded safety switch CTS-C1-BR-CC-FLX-AP-V05-169053; 169053
Transponder-coded safety switch CTS-C1-BR with FlexFunction, connecting cable with flying lead Up to category 4 / PL e according to EN ISO 13849-1 Up to 20 switches...
Price on request
Transponder-coded safety switch CTS-C1-BR with FlexFunction, connecting cable with flying lead
- Up to category 4 / PL e according to EN ISO 13849-1
- Up to 20 switches in series
- Closed-circuit current principle
- Connecting cable, PVC, 5 m, flying lead
- Monitoring outputs OL and OD
Approvals


Electrical connection values
| Fuse | |
| IMP | 1 ... 8 A external |
| UB | 1 ... 8 A external |
| Power consumption | 9 W |
| rated conditional short-circuit current | 100 A |
| Rated insulation voltage Ui | 32 V |
| Rated impulse withstand voltage Uimp | 0.8 kV |
| Operating voltage DC | |
| UB | 24 V DC -15% ... +20% |
| Discrepancy time | max. 10 ms |
| Turn-on time | max. 400 ms |
| EMC protection requirements | Acc. to EN 60947-5-3 |
| Solenoid operating voltage DC | 24 V DC -15% ... +20% reverse polarity protected, regulated, residual ripple<5%, SELV |
| Solenoid duty cycle | 100 % |
| Risk time according to EN 60947-5-3 | max. 200 ms |
| Risk time according to EN 60947-5-3, extension for each additional device | max. 10 ms |
| Switching load | |
| according to UL | DC 24 V, class 2 |
| Safety class | |
| EN IEC 61140 | III |
| Current consumption | |
| IIMP | 500 mA |
| IUB | 50 mA |
| Degree of contamination (external, according to EN 60947-1) | 3 |
| Monitoring outputs Ox/C | |
| Output type | p-switching, short circuit-proof |
| Output voltage | 0.8xUB ... UB V DC |
| Output current | |
| I-configuration (guard lock monitoring inactive) | 1 ... 10 mA |
| L configuration (guard lock monitoring active) | 1 ... 20 mA |
| Safety outputs FO1A/FO1B | |
| Output type | Semiconductor outputs, p-switching, short circuit-proof |
| Output voltage | |
| UFO1A /UFO1B HIGH | UB-4V ... UB V DC |
| UFO1A /UFO1B LOW | 0 ... 1 V DC |
| Output current | |
| L configuration (guard lock monitoring active) | 1 ... 80 mA |
| I-configuration (guard lock monitoring inactive) | 1 ... 75 mA |
| Output current | |
| per safety output FO1A / FO1B | |
| Utilization category | |
| DC-13 I configuration (guard lock monitoring inactive) | 24 V 75 mA |
| DC-13 L configuration (guard lock monitoring active) | 24 V 80 mA |
| Test pulse duration | max. 0.3 ms |
| Test pulse interval | min. 96 ms |
Mechanical values and environment
| Approach speed | max. 20 m/min |
| Extraction force | 25 N |
| Ready delay | max. 5 s |
| Actuating force | 25 N |
| Installation orientation | any |
| Mechanical life | 1 x 10⁶ |
| Retention force | 10 N |
| Shock and vibration resistance | Acc. to EN 60947-5-3 |
| Degree of protection | IP65/IP67/IP69/IP69K |
| Ambient temperature | -20 ... +55 °C |
| Material | |
| Connecting cable | PVC |
| Safety switch housing | Reinforced thermoplastic |
| Switch head cover | Die-cast zinc |
| Locking force Fmax | 3900 N |
| Locking force FZh | 3000 N |
| Guard locking principle | Closed-circuit current principle |
| Connection X1 | |
| Connection type | Connecting cable with flying lead |
| Static bending radius | 8x cable diameter |
| Cable outlet | straight |
| Cable length | 5 m |
| Number of pins | 8 |
| Connection X2 | |
| Connection type | Connecting cable with flying lead |
| Static bending radius | 8x cable diameter |
| Cable outlet | straight |
| Cable length | 5 m |
| Number of pins | 5 |
| Safety outputs FO1A/FO1B | |
| Switching frequency | max. 0.2 Hz |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
| PL | Maximum SIL | PFHD | Category | Mission time | |
|---|---|---|---|---|---|
| Monitoring of the guard position | PL e | 3 | 6.44x10-9 | 4 | 20 y |
| Monitoring of guard locking | PL e | 3 | 6.44x10-9 | 4 | 20 y |
Similar products:
EUCHNER Transponder-coded safety switch CTS-C2-BR-CC-FLX-AP-VAB-169613; 169613
Transponder-coded safety switch CTS-C2-BR with FlexFunction, 2 x M12 Up to category 4 / PL e according to EN ISO 13849-1 Guard locking suitable for process protection
-

(Out of stock)
Price on request
EUCHNER Transponder-coded safety switch CTS-C1-BR-CC-FLX-AP-VAB-169612; 169612
Transponder-coded safety switch CTS-C1-BR with FlexFunction, 2 x M12 Up to category 4 / PL e according to EN ISO 13849-1 Up to 20 switches in series Closed-circuit
-

(Out of stock)
Price on request
EUCHNER Transponder-coded safety switch CTA-L1-BR-U-HA-AP-SH-166257; 166257
Transponder-coded safety switch CTA-BR, M23 Safety switch with guard locking and integrated evaluation electronics Series connection possible Communication functions
-

(Out of stock)
Price on request
EUCHNER Non-contact safety switch CET4-AR-CRA-AH-50F-SH-116285; 116285
Non-contact safety switch CET-AR-..., RC18, with escape release Safety switch with guard locking and integrated evaluation electronics Locking force up to 6500 N
-

(Out of stock)
Price on request
EUCHNER Transponder-coded safety switch CTP-AR, 2 x M12, stainless steel ; 157816
Transponder-coded safety switch CTP-AR, 2 x M12, stainless steel Safety switch with guard locking and integrated evaluation electronics Version with stainless-steel
-

(Out of stock)
Price on request
EUCHNER Safety switch CTP-L1-AS – with AS-i connection, plug connector M12 ; 124987
Safety switch CTP-L1-AS – with AS-i connection, plug connector M12 (closed-circuit current principle) Safety switch with guard locking and integrated evaluation
-

(Out of stock)
Price on request