EUCHNER Transponder-coded safety switch CTP-LBI-AP-U-HA-AE-SA-170618; 170618
Transponder-coded safety switch CTP-LBI-AP, M12 Safety switch with guard locking and integrated evaluation electronics Short circuit monitoring 2 safety outputs...
Price on request
Transponder-coded safety switch CTP-LBI-AP, M12
- Safety switch with guard locking and integrated evaluation electronics
- Short circuit monitoring
- 2 safety outputs (semiconductor outputs)
- Bistable guard locking
- Up to category 4 / PL e according to EN ISO 13849-1
- With plug connector M12
- Unicode
- Door monitoring output
- Approach directions A, B and C (delivery state)
Approvals



Workspace
| Repeat accuracy R | |
| according to EN 60947-5-2 | 10 % |
Electrical connection values
| Fuse | |
| external (operating voltage UB) | 0.5 ... 8 A |
| Power consumption | 1.7 W |
| Rated insulation voltage Ui | 50 V |
| Rated impulse withstand voltage Uimp | 0.5 kV |
| Operating voltage DC | |
| UUB | 24 V DC -15% ... +15% reverse polarity protected, regulated, residual ripple<5%, PELV |
| EMC protection requirements | Acc. to EN IEC 60947-5-3 |
| Utilization category | |
| DC-13 | 24 V 150 mA |
| Solenoid duty cycle | 100 % |
| Switching load | |
| according to UL | 24V DC, Class 2 |
| Safety class | |
| EN IEC 61140 | III |
| Control voltage | |
| UIMP (LOW) | 0 ... 5 V |
| UIMP (HIGH) | 15 ... 24 V |
| Current consumption | |
| IUB (IMP=HIGH) | 440 mA |
| IIMP (IMP=HIGH) | 20 mA |
| IUB (IMP=LOW) | 40 mA |
| Degree of contamination (external, according to EN 60947-1) | 3 |
| Monitoring output OD, OI, OL | |
| Output type | p-switching, short circuit-proof |
| Output voltage | 0.8xUB ... UB V DC |
| Switching current | 1 ... 50 mA |
| Safety outputs FO1A / FO1B | |
| Output type | 2 semiconductor outputs, p-switching, short circuit-proof |
| Output voltage | |
| HIGH U(FO1A) / U(FO1B) | UB-1.5 ... UB V DC |
| LOW U(FO1A) / U(FO1B) | 0 ... 1 V DC |
| Discrepancy time | |
| both safety outputs | max. 10 ms Acc. to EN IEC 60947-5-3 |
| Turn-on time | max. 400 ms |
| Off-state current Ir | max. 0.25 mA |
| Switching current | |
| per safety output FO1A / FO1B | 1 ... 150 mA |
| Test pulse duration | max. 0.3 ms |
| Test pulse interval | min. 100 ms |
Mechanical values and environment
| Approach speed | max. 20 m/min |
| Connection type | 1 plug connector M12, 8-pin |
| Extraction force | 10 N |
| Ready delay | max. 1 s |
| Actuating force | 8 N |
| Installation orientation | any |
| Switching frequency | max. 0.5 Hz |
| Mechanical life | 1 x 10⁶ |
| Overtravel | 5 mm |
| Retention force | 5 N |
| Shock and vibration resistance | Acc. to EN IEC 60947-5-3 |
| Degree of protection | IP67/IP69/IP69K |
| Ambient temperature | |
| at UB = 24 V DC | -20 ... +55 °C |
| Material | |
| Safety switch housing | Reinforced thermoplastic |
| Switch head cover | Die-cast zinc |
| Locking force Fmax | 3900 N |
| Locking force FZh | 3000 N |
| Guard locking principle | BiState |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
| Guard locking control | |
| Mission time | 20 y |
| Category | B |
| Performance Level | PL b |
| PFHD | 2.1 x 10 -9 |
| Guard lock monitoring | |
| Mission time | 20 y |
| Category | 4 |
| Performance Level | PL e |
| PFHD | 4.1 x 10 -9 |
Miscellaneous
| The following applies to the approval according to UL | Operation only with UL Class 2 power supply or equivalent measures; see operating instructions |
| Additional feature | Escape release actuated by pushing |
Similar products:
EUCHNER Transponder-coded safety switch CTP-L2-AP-M-HA-AZ-SA-124729; 124729
Transponder-coded safety switch CTP-AP, M12 Safety switch with guard locking and integrated evaluation electronics Short circuit monitoring 2 safety outputs (semiconductor
-

(Out of stock)
Price on request
EUCHNER Transponder-coded safety switch CTP-L2-AP-M-HA-AZ-SH-123371; 123371
Transponder-coded safety switch CTP-AP, M23 Safety switch with guard locking and integrated evaluation electronics Short circuit monitoring 2 safety outputs (semiconductor
-

(Out of stock)
Price on request
EUCHNER Transponder-coded safety switch CTP-L2-AP-U-HA-AE-SA-136841; 136841
Transponder-coded safety switch CTP-AP, M12, with escape release Safety switch with guard locking and integrated evaluation electronics Short circuit monitoring
-

(Out of stock)
Price on request
EUCHNER Transponder-coded safety switch CTP-L1-AP-U-HA-AE-SA-EX-156240; 156240
Transponder-coded safety switch CTP-AP, M12, ATEX ATEX version Suitable for use in zones 2 and 22 (gases and dusts) Safety switch with guard locking and integrated
-

(Out of stock)
Price on request
EUCHNER Transponder-coded safety switch CTP-L1-AP-U-HA-AE-SH-123375; 123375
Transponder-coded safety switch CTP-AP, M23, with escape release Safety switch with guard locking and integrated evaluation electronics Short circuit monitoring
-

(Out of stock)
Price on request
EUCHNER Transponder-coded safety switch CTP-L1-AP-U-HA-AE-SII-127640; 127640
Transponder-coded safety switch CTP-AP, 2 x M12, with escape release Safety switch with guard locking and integrated evaluation electronics Direct connection to
-

(Out of stock)
Price on request